Contact us

SINOSOURCE LAB SUPPLIERS
Company Name:Sinosource Lab Supplies Ltd.
Contact Person:Mr.YeWei Chen
Skype: sinosourcelab
WeChat and WhatsApp: +86 138 2500 3364
E-Mail: info@sinosourcelab.com
Tel: 86-20-83235069,83292911
Fax: 86-20-83292962
Mobile: 86-13825003364
Postcode: 510375
Address: Room 805-808, No.1, Weigu 2nd Street, Liwan District, Guangzhou, China
Benchtop Multi-Parameter Analyzers
- M300F-A Benchtop Multi-parameter Analyzer
GENERAL FEATURES
- High resolution LCD display, 5.7 inches.
- Multi-reading feature allows auto-read, timed-read and continuous-read.
- Automatic/Manual temperature compensation ensures accurate results.
- Auto-hold feature senses and locks the measurement endpoint.
- Data Storage 500 sets (GLP-compliant).
- Support for USB or RS-232 communication.
- Reset feature automatically resumes all settings back to factory default options.
- IP54 waterproof.
PH
- 1-5 points calibration with Standard Recognition.
- Selectable pH buffer groups, including NIST, DIN, GB, USA.
- Automatic electrode diagnosis with pH slope and offset display.
ION
- 1-5 points calibration.
- Selectable measurement unit, including μg/L, mg/L, g/L, mmol/L, pX, ppm, ppb, etc.
- Multi-measurement modes are supported, including Direct Reading mode, Standard Addition mode, Sample Addition mode and GRAN mode.
- Over 10 methods are built-in, including F-, Cl-, Br-, I-, NO3-, BF4-, NH4+, K+, Na+, Ca2+, Cu2+, Pb2+, Ag+ and etc., user-defined method is supported.
CONDUCTIVITY
- 1-3 points calibration with Standard Recognition.
- Settable parameters, including cell constant, temperature compensation coefficient and TDS factor.
- Temperature compensation type (none, linear, pure water).
INCLUDES
- E-301-QC 3 in 1 pH composite electrode
- DJS-1VTC EC electrode.
- NIST pH standard solution(4.01, 7.00, 10.01) , 50ml/vial
- 1413μS/cm EC standard solution, 50ml, 1 vial
- REX-5 electrode stand
PRODUCT SPECIFICATIONS
Model
|
M300F-A
|
|
Parameters
|
pH/EC/ISE/Temp. (mV/pX/Resistivity/TDS/Sal.)
|
|
pH
|
Range
|
-2.00 to 20.00 pH
|
Resolution
|
0.1, 0.01 pH
|
|
Accuracy
|
±0.01 pH
|
|
Calibration Points
|
Up to 5
|
|
Standard Customization
|
Yes
|
|
Standard Recognition
|
NIST, GB, USA and DIN buffers
|
|
Slope Limit
|
Yes
|
|
mV
|
Range
|
-2000.0 to 2000.0 mV
|
Resolution
|
0.1 mV
|
|
Accuracy
|
±0.3 mV or ±0.1%
|
|
pX
|
Range
|
-2.00 to 20.00 pX
|
Resolution
|
0.1, 0.01 pX
|
|
Accuracy
|
±0.01 pX
|
|
Calibration Points
|
Up to 5
|
|
ISE
|
Range
|
1.000e-9 to 9.999e+9
|
Unit
|
mol/L, mmol/L, g/L, mg/L, μg/L, ppm, ppb
|
|
Resolution
|
Up to 4 significant digits
|
|
Accuracy
|
±0.5%
|
|
Calibration Points
|
Up to 5
|
|
Conductivity
|
Range
|
0.000 μS/cm to 1000 mS/cm
|
Resolution
|
0.001 μS/cm minimum,
various with range selection
|
|
Accuracy
|
±1.0% FS
|
|
Reference Temperature
|
20, 25 ºC
|
|
Calibration Points
|
Up to 3
|
|
Standard Recognition
|
84μS/cm, 1413μS/cm, 12.88mS/cm
|
|
Resistivity
|
Range
|
5.00 Ω·cm~20.00 MΩ·cm
|
Resolution
|
0.01 Ω·cm minimum
|
|
Accuracy
|
±1.0% FS
|
|
TDS
|
Range
|
0.00mg/L~300g/L
|
Resolution
|
0.01mg/L minimum, various with range selection
|
|
Accuracy
|
±1.0% FS
|
|
Salinity
|
Range
|
0.0~80.0 ppt
|
Resolution
|
0.1ppt
|
|
Accuracy
|
±2ppt
|
|
Temperature
|
Range
|
-5 to 110 ºC, 23 to 230 ºF
|
Unit
|
ºC, ºF
|
|
Resolution
|
0.1
|
|
Accuracy
|
±0.2
|
|
Measurement
|
Reading Mode
|
Auto Read (Fast, Medium, Slow), Timed, Continuous
|
Reading Prompts
|
Reading, Stable, Locked
|
|
Temp. Compensation
|
ATC, MTC
|
|
Data management
|
Data Storage
|
500 results each
|
GLP Features
|
Yes
|
|
Inputs
|
pH Electrode
|
BNC(Q9)
|
DO with Temp. Probe
|
4-pin aviation connector
|
|
Conductivity with Temp. Probe
|
5-pin aviation connector
|
|
Outputs
|
USB
|
PC
|
RS 232
|
printer
|
|
Display options
|
Backlight
|
Yes
|
Auto Shutdown
|
1~60 min, off
|
|
IP Rating
|
IP54
|
|
Date and Time
|
Yes
|
|
General
|
Power
|
AC Adapter, 100-240V AC input, DC9V output
|
Dimensions
|
242×195×68 mm
|
|
Weight
|
900g (1.98 lb)
|
|
Dimensions (Carton)
|
370×305×330 mm
|
|
Weight (Gross)
|
3.5 kg
|